Chlorine, Ozone, UV or Silver: How Yacht Water Treatments Compare
Each treatment does one job well and leaves gaps. Here is what WHO, the US EPA and a National Academies report say about chlorine, UV, ozone and copper-silver.
Scientific review by Linda Abenaim, Biologist ·
Only chlorine gives protection all the way along the pipes. The WHO Guide to Ship Sanitation says UV light has no residual effect, and the US EPA says ozone does not leave a residual either, so it needs a second disinfectant. Copper-silver is slower and depends on the water chemistry, according to a National Academies report.
Four tools, four jobs
Yacht water can be treated in several ways. Chlorine is added to the water. UV light passes through it. Ozone is bubbled into it. Copper and silver ions are released into it. Each one kills bacteria in a different way, and each has a weak spot.
The important question is not which is best. It is which one covers the gap left by the others. This guide explains the gaps. For the wider routine, see our water safety plan guide.
What the sources say
The WHO Guide to Ship Sanitation is written for ships. The US EPA manuals are written for public water systems on land, and the National Academies report is about buildings. We say which is which below.
- Chlorine (WHO ship guide): free chlorine of at least 0.5 mg/l after at least 30 minutes of contact, and at delivery points ideally no less than 0.2 mg/l and no more than 5 mg/l. The residual should be kept through the whole distribution system. It also helps control Legionella.
- UV (WHO ship guide): UV light has no residual effect, and all the water needs direct contact with the light. If the water is cloudy, pre-filters should be used first. The guide describes it as of limited value in controlling viruses at common doses.
- UV (US EPA, land): UV leaves no residual, and the dose depends on how clear the water is. Lamp sleeves that foul deliver less light.
- Ozone (US EPA, land): ozone does not provide a residual in the pipes, so a secondary disinfectant is needed. It can form bromate when the water contains bromide.
- Copper-silver (National Academies 2019, buildings): low cost and low maintenance, but slower acting and dependent on the water chemistry. Legionella in biofilm may be protected, and resistance has been suggested.
The WHO ship guide chapter we read does not mention ozone or silver.
Which treatment leaves a residual?
From the WHO ship guide and the US EPA.
Unsure what your water treatment really does?
Tell us what is fitted. We will suggest what to test.
The key differences
Put together, the sources point to one pattern. A treatment that acts on the water as it passes, like UV or ozone, does not protect the pipes downstream. A treatment that stays in the water, like chlorine, does.
That is why the WHO ship guide asks for a residual to be kept through the distribution system, and why testing at the tap matters more than the label on the equipment.
BiologistLinda Abenaim, Biologist at Ekonore / AirBio
Each treatment acts on microbes in a different way. Some leave a residual in the water that keeps working along the pipes; others act only at the point where the water passes. Knowing which one you have explains why some systems stay clean longer than others.
Linda Abenaim · Biologist, Ekonore / AirBio
Ask whether your treatment leaves a measurable residual in the pipes. If it does not, the distribution system needs regular checks of its own.
- Residualkeeps working downstream
- Point of useacts only where water passes
- Checkstest results confirm it works
What to check on a yacht
What is fitted. Which treatment does the yacht have, and where does it sit in the line?
Residual at the tap. Is free chlorine measured at the far end of the system? See our water testing guide.
UV unit. Are the lamp and sleeve cleaned and replaced as the maker says, and is the water clear before it?
Ozone or silver. Is there a second disinfectant behind it, and is the result tested?
Tanks. Treatment does not replace cleaning. See tank inspection.


A treatment unit on the plant-room wall proves nothing. The result at the tap does. That is where we measure.
Francesco Colombo
CEO · AirBio Marine, a division of AirBio (Ekonore S.r.l.)
Test your water treatmentVerified reviews on Trustpilot
Reviews of La BioDisinfestazione | Ekonore Italia, the group AirBio Marine belongs to.
What we do
We do not tell you which treatment to buy. Whatever the yacht uses, we can test whether it is working: sampling the water at the tap, checking the residual, and cleaning and sanitizing the tanks and lines when the results ask for it.
See our water sampling and water system sanitization services.

How we check a yacht’s water treatment, step by step
Five steps, planned with the crew.
Review
We note what treatment is fitted and how it is run.
Measure
We check the residual and temperature at several taps.
Sample
Samples are taken and sent to a laboratory.
Sanitize
Tanks and lines are cleaned if the results ask for it.
Report
You receive readings, lab results and a written summary.

We take the same samples before and after work, so you can see what changed.
Francesco Colombo
CEO · AirBio Marine, a division of AirBio (Ekonore S.r.l.)
Speak to our teamA sample routine
A starting point built on the WHO ship guide. Adjust it to the equipment fitted.
- Regularly: measure free chlorine and temperature at the taps, not just at the plant.
- As the maker says: clean the UV sleeve, replace the lamp and change filters.
- At planned intervals: sample the water for a laboratory.
- If you use ozone or silver: confirm there is a second disinfectant, and test what arrives at the tap.
- After a lay-up or repair: clean and disinfect before use.
- Always: keep readings and lab reports on file.
Warning signs
- No chlorine residual at the far end of the system.
- Cloudy water going into a UV unit.
- A treatment unit nobody has serviced.
- Relying on one treatment and never testing the tap.
See also cloudy yacht water and hot water and Legionella.
FAQ
Which treatment is best for yacht drinking water?
No single one covers everything. The WHO ship guide asks for a disinfectant residual throughout the system, which chlorine provides and UV does not. Combine treatments and test at the tap.
Does UV leave protection in the pipes?
No. The WHO ship guide says UV has no residual effect, and the US EPA says the same.
Does ozone leave protection in the pipes?
No. The US EPA says ozone does not provide a residual in distribution, so a secondary disinfectant is needed.
Is copper-silver ionisation a good choice?
A 2019 National Academies report for buildings says it is low cost and low maintenance, but slower acting, dependent on the water chemistry, and less effective in biofilm.
What chlorine level does the WHO ship guide give?
At least 0.5 mg/l free chlorine after at least 30 minutes of contact, and at delivery points ideally between 0.2 and 5 mg/l.
Do the EPA documents apply to yachts?
They are written for public water systems on land. Use them to understand how each treatment behaves, not as ship rules.
Sources
- World Health Organization — Guide to Ship Sanitation, 3rd edition (2011), water chapter: chlorine, residual, UV.
- US Environmental Protection Agency — Alternative Disinfectants and Oxidants Guidance Manual, EPA 815-R-99-014 (1999): ozone, residuals and bromate (written for public water systems; copy hosted by SSWM).
- US Environmental Protection Agency — Ultraviolet Disinfection Guidance Manual for the Final LT2ESWTR (2006): UV dose, clarity and residual (public water systems; copy hosted by Purdue).
- National Academies of Sciences, Engineering, and Medicine — Management of Legionella in Water Systems (2019): copper-silver ionisation (buildings).
Not sure your water treatment is working?
We test the water at the tap and tell you what the results show.
Speak to a marine technicianRelated on AirBio Marine
Ready to test your yacht’s water?
Sampling at the tap, cleaning if needed, and a written report, at the berth.
Verified reviews on Trustpilot
Reviews of La BioDisinfestazione | Ekonore Italia, the group AirBio Marine belongs to.
Tell us about the yacht
Yacht length, marina, systems and what you have noticed on board. A technician reads the message and calls you back to plan the survey.
"*" indicates required fields
Where we work
Italian Riviera and Tuscany marinas and yards — Viareggio, La Spezia, Portofino, Genoa, Sanremo, Livorno, Argentario — and other Mediterranean ports on request.
Documented work
Every job ends with a technical report and photos for the yacht's records.